Working principle |
CO2:NDIR |
PM:Laser scattering principle |
Measurement range |
PM2.5:0~1000μg/m³ |
CO2:0~5000ppm |
Temperature:-10℃~50℃ |
Humidity:0%~95%RH |
PM2.5 Measurement accuracy |
≤ 100μg/m³:±10μg/m³ |
> 100μg/m³:±10% reading |
(Reference Instrument TSI 8530,25±2℃,50±10%RH) |
CO2 Measurement accuracy |
±(50ppm+5% reading)@ 0~50℃ |
Temperature Measurement accuracy |
±1℃ |
Humidity Measurement accuracy |
±8%RH |
PM Response time T90 |
≤8s |
CO2 Response time T90 |
<120s |
Working condition |
-10~50℃,0~95%RH(Non-condensing) |
Storage condition |
-20~60℃,0~95%RH(Non-condensing) |
Working voltage |
DC 12V |
Working current |
<140mA |
Standby current |
≤80mA |
Signal Output |
RS485 |
Installation hole distance |
60mm(standard) |
Dimension |
86*86*24.9 mm |
Lifetime |
PM:≥5 years |
CO2:≥10 years |