Operating principle |
Laser scattering |
Measured particle range |
0.3μm ~ 10μm |
Measurement range |
0~1,000μg/m³ |
Resolution |
1μg/m³ |
Working condition |
-10°C ~ 60°C,0-95%RH (non-condensing) |
Storage condition |
-30°C ~ 70°C, 0-95%RH (non-condensing) |
Maximum consistency error for PM1.0&PM2.5 |
0~100μg/m³, ±15μg/m³ |
101~1000μg/m³, ±15% reading |
Condition: 25±2℃,50±10%RH, |
Reference instrument: GRIMM |
Dust Source: Cigarette+Arizona A1 |
Maximum consistency error for PM10 |
0 ~100μg/m³, ±30μg/m³ |
101 ~ 1,000μg/m³, ±30% reading |
Condition: 25±2℃,50±10%RH, |
Reference instrument: GRIMM |
Dust Source: Cigarette+Arizona A1 |
Response time |
1sec |
Time to first reading |
≤ 8 seconds |
Power supply |
DC 5V±0.1V, ripple wave<50mV |
Working current |
≤100mA |
Standby current |
≤200μA |
Dimensions |
48×40×12mm |
Digital output 1 (default) |
UART_TTL_3.3V(default); |
I2C_3.3V/5V(default) |
Digital output 2 |
PWM (customized) |
Output method |
Default by active output after powering on, sampling time interval should be over 1,000ms |
MTTF |
37,297 hrs (continuous turn on) |